GCK Withdrawable Low Voltage Switchgear

GCK Withdrawable Low Voltage Switchgear
GCK Withdrawable Low Voltage Switchgear

GCK Withdrawable Low Voltage Switchgear

The cabinet frame construction utilized in the GCK(L) system is modular, and different standard components may be put in the cabinet to meet a variety of usage needs. The withdrawable unit uses aluminum alloy sliding guide rails and a spiral propulsion mechanism, with a clear operating position and simple, dependable operation.

The GCK(L) system low-voltage withdrawable switchgear is suited for all power generating, distribution, and power usage applications, including power systems, petrochemicals, industrial and mining businesses, civil buildings, etc.

GCK is a withdrawable-type low voltage switchgear family — outgoing units ride in drawers on aluminium alloy guide rails with a screw propulsion mechanism, so a feeder or motor starter can be rolled out to the test position, serviced, or swapped without de-energizing the section behind it. The modular frame takes different standard components to cover power centers and motor control centers in power systems, petrochemical plants, industrial and mining enterprises, and civil buildings.

We build GCK boards drawer by drawer from your load schedule — drawer assignments, interlocks, and spare positions planned around the growth of the plant. The fabrication floor behind these boards has delivered 4,000+ electrical projects since 2010, with CNC-machined frames plus in-house wiring and testing making every drawer a repeatable, interchangeable unit.

Feature of Withdrawable Low Voltage Switchgear

  • Standard modular design allows for the assembly of protection, operation, conversion, control, regulation, measurement, instructions, and other standard units. Users can mix and match frame constructions and drawer units to meet their specific demands.

  • Made of C-profiles, the module measures 25mm. It offers high structural adaptability and flexible assembly to accommodate a variety of configurations.

  • Requirements for form protection and usage environment. All structural components of the cabinet are galvanised and passivated. The door panels and side doors that surround the cabinet frame are electrostatically sprayed.

  • The product boasts high mechanical strength and dependable insulation, ensuring safety and dependability. Additionally, all functional elements are replaceable. After a failure, the identical functional unit can be replaced.
    Reduce power outages and increase power supply dependability.

  • The projects that have passed numerous high-performance tests are listed below:
    1. Earthquake Resistance Test (seismic intensity level 9)
    2. Arc burning test (100kA/0.5 seconds)
    3. Salt spray test (96 hours).
    4. High altitude test (4000 m)

Technical Parameters

ProjectUnitNumerical value
Rated voltageVAC380,AC660
Rated powerHz50/60
Rated operating currentHorizontal busALess than or equal 4000
Vertical busALess than or equal 6000
Rated short-time withstand current (1s)KA30,50,80
Rated peak withstand currentKA63,105,176
Dielectric strengthV/1min2500
Rated insulation voltageV660,1000
Control motor capacityKW0.5~155
Protection levelIP30/IP40
Dimensions(L*W*H)mm600(800/1000)*600(800/1000)*2200

Key Specifications & Options

The configuration below reflects the options we build to order for GCK withdrawable low voltage switchgear. Every parameter can be adjusted to match your drawings and site conditions — send us your requirements and our engineers will confirm what applies to your project.

ParameterOptions / Typical Range
Assembly typeWithdrawable (drawer-type) low voltage switchgear for power center and motor control duty
Rated voltageAC 50 Hz, 380/400 V working voltage on a 660 V insulation class
Drawer unitsDrawer ratings and slot counts configured to your feeder and motor schedule
Main busbar currentSized to the load schedule of the line-up
Drawer mechanicsAluminium slide rails, screw propulsion, and interlocked test/disconnect/operating positions
Protection degreeIP30–IP40 typical executions
Applicable standardsGB 7251 series for LV assemblies, corresponding to IEC 61439
Typical applicationsMotor control centers, process feeders, petrochemical and mining plants, high-rise distribution

Frequently Asked Questions

GGD or GCK — which one fits my project?

The question is maintenance access: if a circuit can wait for a planned shutdown, fixed-type GGD is the economical answer; if operations cannot tolerate losing the section while one feeder is serviced, GCK drawers let that unit roll out on its own. Motor-heavy continuous loads — pumps, fans, compressors — are the classic GCK case.

What are the maintenance advantages of withdrawable drawers?

A drawer rolls to a disconnected test position without opening the section: faults are isolated in minutes, a spare drawer restores the feeder the same shift, and starters can be bench-serviced off-line. Sections stay energized, which matters most in continuous process plants.

Are drawers interchangeable between positions of the same rating?

Drawers of the same unit rating and scheme are interchangeable within a line-up built as one assembly — positions share the compartment interfaces. We build and wire to keep that promise and can supply spare drawers configured to your schemes for the maintenance store.

What standards govern GCK assemblies?

GCK falls under the GB 7251 series for low voltage assemblies, corresponding to IEC 61439 — covering design verification, internal separation, and short-circuit withstand. We reference these standards in design and deliver assembly documentation with the board.