Removable AC Metal Clad Switchgear

KYN Removable AC Metal Clad Switchgear

KYN28-24(Z) series alternating-current metal-clad and metal-enclosed with drawable switchgear(hereinafter referred to as “switchgear”) is a complete set of power distribution unit of three-phasesingle bus and single bus section system of 20kV and AC50(60)Hz.

This switchgear is mainly applicable to power plants, power transmitting of middle and small sized generators,distribution of industrial and mining enterprises, electricity receiving and transmitting of secondary substations,as well as starting of large high-voltage motors, etc, realizes control protection and monitoring.

Technical Parameters

NoItemUnitParameter
1Rated voltageKV24
2Rated frequencyHz50 / 60
3Rated insulation level1Min. frequency toleranceKVInterphases65Isolated fracture79
Lightning impulse tolerance voltage125145
Auxiliary control voltageV2000
4Rated currentA630, 1250, 1600, 2000, 2500, 3150
5Rated short circuit breaking currentKA
6Rated short circuit closing current (Peak)KA
7Rated short time withstand current 4sKA
8Rated peak endurance currentKA
9Auxiliary control circuit rated voltageV
10Protective levelIP4X (Doors of compartments are open, the degree is up to IP2X)
11Outline dimensions (W x D x P)mm800x1800x2300; 1000x1800x2300
12Total weightKg750 ~ 1440

Model explanantion

59dc3f057f922059f774919fece45b52

Feature of Removable AC Metal Clad Switchgear

  1. The busbar adopts heat-shrinkable insulating material or epoxy-coated insulating means to optimize the electrode shape so that the cabinet structure is compact and the floor space is reduced.
  2. The cabinet is made of high-quality cold-rolled steel plates and imported aluminum-zinc coated plates, which are formed by CNC sheet metal processing and are connected by high-strength bolts, nuts, and rivet nuts.
  3. Insulation boards are installed in the busbar room, handcart room, and cable room in the cabinet, and the insulation level is greatly improved.
  4. Can be configured with domestic VS1-24 vacuum circuit breaker or Schneider’s VH4 or Alstom FP series sulfur hexafluoride circuit breaker to meet the needs of different users.
  5. The combined valve can be opened flexibly. As the circuit breaker is pulled out, the valve will be automatically closed and forced to lock, preventing the danger of accidentally touching high voltage.
  6. The friendly man-machine interface makes the operation of the switch cabinet programmatic and formulaic, and the operator can see it at a glance.
  7. The main wiring scheme can reach more than 160 kinds, and the structure has strong adaptability, which can meet the needs of different users

Removable AC Metal Clad Switchgear Structure

Structure