Fire Electrical Control Cabinet Manufacturer

ホーム - 電気制御盤 - 防火電気制御盤

Fire Electrical Control Cabinet Products

One Control Four Fire Inspection Control Cabinet

One Control Four Fire Inspection Control Cabinet

Fire Pump Inspection Control Cabinet

Fire Pump Inspection Control Cabinet

132KW Fire Pump Control Cabinet

132KW Fire Pump Control Cabinet

Fire Emergency Starting Cabinet

Fire Emergency Starting Cabinet

Fire Dual Power Supply Control Cabinet

Fire Dual Power Supply Control Cabinet

One Control Seventy Fire Signal Control Cabinet

One Control Seventy Fire Signal Control Cabinet

Air Conditioning Circulation Pump Control Cabinet

Air Conditioning Circulation Pump Control Cabinet

110KW One Control And Two Fire Inspection Cabinets

110KW One Control And Two Fire Inspection Cabinets

132 Kw One Control And Two Integrated Fire Control Cabinets

132KW One Control And Two Integrated Fire Control Cabinets

110kw Fire Protection Dual Power Supply Control Cabinet

110kW Fire Protection Dual Power Supply Control Cabinet

Fire Pump Emergency Starting Cabinet

Fire Pump Emergency Starting Cabinet

Fire Linkage Control Cabinet

Fire Linkage Control Cabinet

Fire Electrical Control Cabinet Process

01

電気計画と設計

電気キャビネットを開発する初期段階では、製品の仕様と顧客のニーズを慎重に検討する必要がある。

02

コンポーネントのレイアウトとデザイン

このプロセスでは、パフォーマンス、セキュリティ、使いやすさのバランスをとるために、各コンポーネントを慎重に配置する必要がある。

03

コンポーネントの組み立て

各コンポーネントを電気キャビネットに取り付け、電磁干渉を防ぐためにACコンポーネントとDCコンポーネントのゾーニングに特別な注意を払ってください。

04

取り付けと配線

配線作業は、ベストプラクティスと安全慣行に従う必要があります。正しいインストールと配線手順は、機器の動作の安全性と効率を保証するために重要です。

05

テストと品質管理

電気キャビネットの設計と性能は、すべてのコンポーネントが意図したとおりに動作し、実際の操作で安全要件を満たしていることを確認するために、多くのテストによって検証されます。

06

ドキュメンテーションおよびメンテナンスガイド

電気キャビネットの長期的な使用とメンテナンスのために、トラブルシューティングガイドや定期的なメンテナンススケジュールなど、詳細な操作・メンテナンスマニュアルが用意されています。

一般 アプリケーション of Fire Electrical Control Cabinet

交通インフラ

交通インフラ

マリンアプリケーション

マリンアプリケーション

Key Aspects Of Fire Electrical Control Cabinet Manufacturing

1.デザインとエンジニアリング
  • 構造設計: Creates a strong, fire-resistant casing. Considers material strength, thermal insulation, and usability. Enforces compliance with fire safety standards and regulations.

  • 電気システム設計: Plan the configuration of fire detection, alarm, and suppression control components. Concentrates on dependability, redundancy, and fail-safe functioning. Includes backup power systems.

  • Heat Management: Cooling systems are designed to maintain appropriate temperatures. It is critical to ensure the reliability of electronic components in fire conditions. Special materials that are heat resistant may be used.

  • Interface Layout: Organizes displays and controls for easy, intuitive access during an emergency. Prioritizes visibility and simplicity of usage in difficult situations.
2.キーコンポーネント
  • Fire Alarm Control Panel: The central unit monitors and controls fire detection and alarm systems. Processes detector signals, triggers alerts, and communicates with building systems.
  • Power supplies: Provides both primary and backup power. Includes battery systems to provide continuous functioning during power outages. Designed to be reliable in emergency scenarios.
  • Input/Output Modules: Integrate with a variety of detectors, alarms, and suppression systems. Handle both digital and analog signals to provide full fire monitoring and control.
  • Communication Modules: Allow connectivity with building management systems and emergency services. Support many protocols for interoperability and remote monitoring.
  • Circuit Protection: Contains sophisticated circuit breakers and surge protectors. Designed to keep the system intact amid fire-related electrical interruptions.
3.素材の選択
  • Fire-resistant enclosure: Uses materials such as fire-resistant steel or specific composites. Designed to keep the structure intact and its components safe during a fire.

  • High Temperature Wiring: Uses fire-resistant wires and insulation. Ensures that vital systems remain operational during fires.

  • EMI shielding: Contains chemicals that protect sensitive electronics from interference. It is critical to sustain communication and control operations during an emergency.
4.製造工程
  • Precision Fabrication: Precision cutting and drilling are achieved with the use of modern CNC machining technology. Ensures appropriate component fit and preserves fire-resistant qualities.
  • 専門的な組み立て: Involves meticulous component integration, with a focus on heat-resistant connections. Skilled personnel with experience installing fire safety systems are required.
  • Rigorous Testing: This includes fire resistance testing, functioning tests, and simulated emergency scenarios. Ensures the cabinet fulfills or exceeds fire safety requirements.
5.品質管理
  • Fire Rating Verification: Tests cabinets' fire resistance duration. Ensures that they meet or exceed the fire rating requirements.
  • 機能テスト: Simulates numerous fire scenarios to ensure proper system reaction. Tests all alarm, detection, and suppression control functions.
  • Environmental Stress Tests: Cabinets are subjected to intense heat and smoke conditions. Tests performance and durability in simulated fire conditions.
6. Compliance and Certification
  • Fire Safety Standard: Conforms to standards such as NFPA, EN 54, and local fire codes. Thorough documentation is usually required, as well as third-party validation.
  • Electric Safety: Meets electrical safety and performance criteria. Includes particular considerations for functioning during a fire emergency.
  • Industry Specific Requirements: Meets extra safety requirements for high-risk areas such as petrochemical plants and data centers.