GCS 低压抽出式开关柜
GCS-type low-voltage withdrawable switchgear is suitable for use in low-voltage distribution systems such as power plants, substations, petrochemical sectors, factories and mines, high-rise buildings, and so on, as well as for electric energy conversion, distribution, and control such as capacitance compensation.
The GCS type low-voltage withdrawable switchgear has high making and breaking capabilities, good dynamic and thermal stability, an advanced and reasonable structure, a flexible electrical scheme, a high protection level, safety and reliability, ease of maintenance, and excellent technical performance indicators.
Feature of Low Voltage Withdrawable Switch Cabinet
The cabinet frame uses double-folding technology with aluminum-zinc-coated steel plates. The frame has modular holes spaced at 25mm intervals (K profile). The frame is simple to construct and durable. The entire frame is joined exactly by transverse and longitudinal bolts, and the frame structure requires no maintenance.
The shell is electroplated and powder coated. The top cover of the horizontal busbar region may be removed for easier on-site busbar installation.
Each functional room is clearly segregated, with divisions primarily divided into functional unit rooms and cable rooms. Each unit's functions are autonomous and have no effect on one another.
The horizontal busbar is mounted flat beneath the cabinet, increasing its capacity to withstand the electric power generated by a short-circuit current.
It features a drawer-style construction and can accommodate up to 36 circuits. The rated current of the circuit is 400A or less. The drawer circuit may be converted to three positions without compromising its protection level.
Each unit may accommodate up to 11 drawers or 22 1/2 drawers.
The drawer has five positions: opening, shutting, testing, pulling out, and isolating, and it features clear signals that correspond to sound, light, and text directions.
GCS Low Voltage Withdrawable Switch Cabinet Technical Parameters
Rated insulation voltage Ui | exchange | 690V、1000V | ||
---|---|---|---|---|
Rated operating voltage Ue | Main circuit/ auxiliary circuit | exchange | 400V、660V | |
exchange | 380V、200V | |||
Direct current | 200V、100V | |||
Rated impulse withstand voltage Uimp | 8KV | Vertical busbar rated current | 1000V | |
Overvoltage level | Ⅲ | Rated peak withstand current (0.1S) IPK | Vertical 105kA | |
pollution level | 3 | Level 176kA | ||
Rated frequency | 50(60)Hz | Rated peak withstand current (0.1S) IPK | Vertical 80kA | |
Horizontal bus rated current | Ie≤4000A | Level 80kA | ||
Enclosure rating | IP30、IP40 | Dimensions2200x(400,600,800,1000)x(600,800,1000) |