{"id":30518,"date":"2024-06-10T08:16:24","date_gmt":"2024-06-10T08:16:24","guid":{"rendered":"https:\/\/electricalcabinet.net\/?page_id=30518"},"modified":"2026-09-09T00:01:17","modified_gmt":"2026-09-08T16:01:17","slug":"solid-insulated-ring-network-switchgear","status":"publish","type":"page","link":"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/","title":{"rendered":"GTXGN Painel de distribui\u00e7\u00e3o de rede em anel com isolamento s\u00f3lido"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"30518\" class=\"elementor elementor-30518\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-12eb90ef e-flex e-con-boxed e-con e-parent\" data-id=\"12eb90ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-391018d3 e-flex e-con-boxed e-con e-parent\" data-id=\"391018d3\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-38c3160a e-con-full e-flex e-con e-child\" data-id=\"38c3160a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-39b1d2d7 elementor-widget elementor-widget-image\" data-id=\"39b1d2d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc.jpg\" class=\"elementor-animation-pulse-shrink attachment-large size-large wp-image-30525\" alt=\"Gtxgn-12\/24 - Painel de distribui\u00e7\u00e3o de rede em anel com isolamento s\u00f3lido\" srcset=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc.jpg 800w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-300x300.jpg 300w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-150x150.jpg 150w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-768x768.jpg 768w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-430x430.jpg 430w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-700x700.jpg 700w\" sizes=\"(max-width: 800px) 100vw, 800px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3aea8d1f e-con-full e-flex e-con e-child\" data-id=\"3aea8d1f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6b75b17b color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"6b75b17b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>GTXGN-12\/24 series solid insulated ring network switch cabinet is the main unit switch of solid composite insulated ring network used in medium voltage distribution network.<\/p><p>New environmentally friendly materials Vacuum arc extinguishing Direct-acting isolation switch<\/p><p>GTXGN-12\/24 series solid insulated ring network switch cabinets are the main switch units of solid-composite-insulated ring networks in medium voltage distribution \u2014 vacuum arc interruption and a direct-acting isolation switch encapsulated in new environmentally friendly insulating materials. No position in the cabinet depends on gas insulation, which makes the family the natural answer where environmental rules or corporate policy restrict SF6 equipment.<\/p><p>We build solid-insulated ring cabinets to your network configuration \u2014 unit arrangements, cable positions, and automation options assembled under the same quality system that has delivered 4,000+ projects since 2010, with in-house CNC fabrication, wiring, and testing through to shipment.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3c3160fe e-flex e-con-boxed e-con e-child\" data-id=\"3c3160fe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9cdd50f elementor-widget elementor-widget-button\" data-id=\"9cdd50f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm elementor-animation-pulse-shrink\" href=\"#elementor-action:action=popup:open&settings=eyJpZCI6IjI2NzE4IiwidG9nZ2xlIjpmYWxzZX0=\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obter um or\u00e7amento<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c41fc6f elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"4c41fc6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ce874f4 e-flex e-con-boxed e-con e-child\" data-id=\"ce874f4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59a26e74 elementor-widget elementor-widget-wd_social_buttons\" data-id=\"59a26e74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_social_buttons.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t<link rel=\"stylesheet\" id=\"wd-social-icons-css\" href=\"https:\/\/electricalcabinet.net\/wp-content\/themes\/woodmart\/css\/parts\/el-social-icons.min.css?ver=7.5.1\" type=\"text\/css\" media=\"all\" \/> \t\t\t\n\t\t\t<div class=\"wd-social-icons wd-layout-inline icons-design-default icons-size-small color-scheme-dark social-share social-form-circle text-left\">\n\n\t\t\t\t\t\t\t\t\t<span class=\"wd-label\">Partilhar:<\/span>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<a rel=\"noopener noreferrer nofollow\" href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/\" target=\"_blank\" class=\"wd-social-icon social-facebook\" aria-label=\"Facebook social link\">\n\t\t\t\t\t\t<span class=\"wd-icon\"><\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<a rel=\"noopener noreferrer nofollow\" href=\"https:\/\/x.com\/share?url=https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/\" target=\"_blank\" class=\"wd-social-icon social-twitter\" aria-label=\"X social link\">\n\t\t\t\t\t\t<span class=\"wd-icon\"><\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<a rel=\"noopener noreferrer nofollow\" href=\"https:\/\/www.linkedin.com\/shareArticle?mini=true&url=https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/\" target=\"_blank\" class=\"wd-social-icon social-linkedin\" aria-label=\"Linkedin social link\">\n\t\t\t\t\t\t<span class=\"wd-icon\"><\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<a rel=\"noopener noreferrer nofollow\" href=\"https:\/\/api.whatsapp.com\/send?text=https%3A%2F%2Felectricalcabinet.net%2Fpt%2Felectrical-switchgear%2Fhigh-voltage-switchgear%2Fsolid-insulated-ring-network-switchgear%2F\" target=\"_blank\" class=\"whatsapp-desktop  wd-social-icon social-whatsapp\" aria-label=\"WhatsApp social link\">\n\t\t\t\t\t\t<span class=\"wd-icon\"><\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\n\t\t\t\t\t<a rel=\"noopener noreferrer nofollow\" href=\"whatsapp:\/\/send?text=https%3A%2F%2Felectricalcabinet.net%2Fpt%2Felectrical-switchgear%2Fhigh-voltage-switchgear%2Fsolid-insulated-ring-network-switchgear%2F\" target=\"_blank\" class=\"whatsapp-mobile  wd-social-icon social-whatsapp\" aria-label=\"WhatsApp social link\">\n\t\t\t\t\t\t<span class=\"wd-icon\"><\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4b098503 wd-section-stretch e-flex e-con-boxed e-con e-parent\" data-id=\"4b098503\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2fc2eb58 wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"2fc2eb58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t<link rel=\"stylesheet\" id=\"wd-section-title-css\" href=\"https:\/\/electricalcabinet.net\/wp-content\/themes\/woodmart\/css\/parts\/el-section-title.min.css?ver=7.5.1\" type=\"text\/css\" media=\"all\" \/> \t\t\t\t\t\t<link rel=\"stylesheet\" id=\"wd-section-title-style-under-and-over-css\" href=\"https:\/\/electricalcabinet.net\/wp-content\/themes\/woodmart\/css\/parts\/el-section-title-style-under-and-over.min.css?ver=7.5.1\" type=\"text\/css\" media=\"all\" \/> \t\t\t\t\t<div class=\"title-wrapper set-mb-s reset-last-child wd-title-color-primary wd-title-style-underlined wd-title-size-medium text-left\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h2 class=\"woodmart-title-container title wd-fontsize-xl\">Technical Parameters<\/h2> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7419b5c color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"7419b5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n<table class=\"tg\"><thead>\n  <tr>\n    <th class=\"tg-vs4f\" colspan=\"2\">Project<\/th>\n    <th class=\"tg-vs4f\">units<\/th>\n    <th class=\"tg-vs4f\" colspan=\"2\">Parameters<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated voltage<\/td>\n    <td class=\"tg-zkss\">kV<\/td>\n    <td class=\"tg-zkss\">12<\/td>\n    <td class=\"tg-zkss\">24<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated current<\/td>\n    <td class=\"tg-zkss\">A<\/td>\n    <td class=\"tg-zkss\">630<\/td>\n    <td class=\"tg-zkss\">630<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Frequ\u00eancia nominal<\/td>\n    <td class=\"tg-zkss\">Hz<\/td>\n    <td class=\"tg-zkss\">50<\/td>\n    <td class=\"tg-zkss\">50<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" rowspan=\"2\">Rated insulation level<\/td>\n    <td class=\"tg-zkss\">One-minute power frequency withstand voltage: <br>ground, phase-to-phase isolation\/fracture<\/td>\n    <td class=\"tg-zkss\">kA<\/td>\n    <td class=\"tg-zkss\">42\/48<\/td>\n    <td class=\"tg-zkss\">65\/75<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\">Lightning impulse withstand voltage: <br>ground, phase isolation\/fracture<\/td>\n    <td class=\"tg-zkss\">kA<\/td>\n    <td class=\"tg-zkss\">75\/85<\/td>\n    <td class=\"tg-zkss\">125\/145<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated short-time withstand current (main circuit and ground circuit)<\/td>\n    <td class=\"tg-zkss\">A<\/td>\n    <td class=\"tg-zkss\">25<\/td>\n    <td class=\"tg-zkss\">25<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated peak withstand current<\/td>\n    <td class=\"tg-zkss\">kA<\/td>\n    <td class=\"tg-zkss\">50<\/td>\n    <td class=\"tg-zkss\">50<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated short circuit duration<\/td>\n    <td class=\"tg-zkss\">times<\/td>\n    <td class=\"tg-zkss\">3<\/td>\n    <td class=\"tg-zkss\">3<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated dynamic stable current<\/td>\n    <td class=\"tg-zkss\">A<\/td>\n    <td class=\"tg-zkss\">50<\/td>\n    <td class=\"tg-zkss\">50<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated current of fuse circuit (maximum)<\/td>\n    <td class=\"tg-zkss\">s<\/td>\n    <td class=\"tg-zkss\">125<\/td>\n    <td class=\"tg-zkss\">125<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Rated transfer current<\/td>\n    <td class=\"tg-zkss\">A<\/td>\n    <td class=\"tg-zkss\">1700<\/td>\n    <td class=\"tg-zkss\">1700<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Vacuum circuit breaker breaking capacity<\/td>\n    <td class=\"tg-zkss\">kA<\/td>\n    <td class=\"tg-zkss\">25<\/td>\n    <td class=\"tg-zkss\">25<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Load switch mechanical life<\/td>\n    <td class=\"tg-zkss\">Times<\/td>\n    <td class=\"tg-zkss\">5000<\/td>\n    <td class=\"tg-zkss\">5000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Vacuum circuit breaker mechanical life<\/td>\n    <td class=\"tg-zkss\">Times<\/td>\n    <td class=\"tg-zkss\">10000<\/td>\n    <td class=\"tg-zkss\">10000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\">Grounding switch mechanical life<\/td>\n    <td class=\"tg-zkss\">Times<\/td>\n    <td class=\"tg-zkss\">2000<\/td>\n    <td class=\"tg-zkss\">2000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\" colspan=\"2\" rowspan=\"2\">Operating supply voltage<\/td>\n    <td class=\"tg-zkss\" rowspan=\"2\">V<\/td>\n    <td class=\"tg-zkss\">24V DC<\/td>\n    <td class=\"tg-zkss\">24V DC<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-zkss\">220V AC\/DC<\/td>\n    <td class=\"tg-zkss\">220V AC\/DC<\/td>\n  <\/tr>\n<\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9fa45 wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"1f9fa45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"title-wrapper set-mb-s reset-last-child wd-title-color-primary wd-title-style-underlined wd-title-size-medium text-left\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h2 class=\"woodmart-title-container title wd-fontsize-xl\">Technical Parameters<\/h2> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<div class=\"title-after_title set-cont-mb-s reset-last-child wd-fontsize-s\">\n\t\t\t\t\t<ul><li><p>New environmentally friendly materials<\/p><\/li><li><p>Vacuum arc extinguishing<br \/>Direct acting isolation switch<\/p><\/li><li><p>Fully sealed, fully insulated cable entry and exit lines<\/p><\/li><li><p>Modular and scalable<\/p><\/li><li><p>Various wiring options<\/p><\/li><li><p>Visible fracture<\/p><\/li><li><p>Electrically operated, FTU<\/p><\/li><\/ul>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-71b7ac6c wd-section-stretch e-flex e-con-boxed e-con e-parent\" data-id=\"71b7ac6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e873c44 wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"4e873c44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t<link rel=\"stylesheet\" id=\"wd-section-title-style-simple-and-brd-css\" href=\"https:\/\/electricalcabinet.net\/wp-content\/themes\/woodmart\/css\/parts\/el-section-title-style-simple-and-brd.min.css?ver=7.5.1\" type=\"text\/css\" media=\"all\" \/> \t\t\t\t\t<div class=\"title-wrapper set-mb-s reset-last-child wd-title-color-primary wd-title-style-simple wd-title-size-medium text-left\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h2 class=\"woodmart-title-container title wd-fontsize-xl\">PRODUTOS RELACIONADOS<\/h2> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-555fe16 elementor-grid-3 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-posts--show-avatar elementor-card-shadow-yes elementor-posts__hover-gradient elementor-widget elementor-widget-posts\" data-id=\"555fe16\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]},&quot;cards_columns&quot;:&quot;3&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;,&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-30519 page type-page status-publish has-post-thumbnail hentry\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fully-sealed-and-fully-insulated-inflatable-ring-network-switchgear\/\" tabindex=\"-1\" ><div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"400\" height=\"167\" src=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-400x167.jpg\" class=\"attachment-medium size-medium wp-image-30709\" alt=\"XGN Fully Sealed And Fully Insulated Inflatable Ring Network Switchgear\" srcset=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-400x167.jpg 400w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-1300x542.jpg 1300w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-768x320.jpg 768w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-1536x640.jpg 1536w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-430x179.jpg 430w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-700x292.jpg 700w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1-150x63.jpg 150w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN-12-24-1.jpg 1920w\" sizes=\"(max-width: 400px) 100vw, 400px\" title=\"\"><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__avatar\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fully-sealed-and-fully-insulated-inflatable-ring-network-switchgear\/\" >\n\t\t\t\tXGN Fully Sealed And Fully Insulated Inflatable Ring Network Switchgear\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fully-sealed-and-fully-insulated-inflatable-ring-network-switchgear\/\" aria-label=\"Read more about XGN Fully Sealed And Fully Insulated Inflatable Ring Network Switchgear\" tabindex=\"-1\" >\n\t\t\tLer mais \"\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-30518 page type-page status-publish has-post-thumbnail hentry\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/\" tabindex=\"-1\" ><div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"400\" height=\"167\" src=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-400x167.jpg\" class=\"attachment-medium size-medium wp-image-30710\" alt=\"GTXGN Painel de distribui\u00e7\u00e3o de rede em anel com isolamento s\u00f3lido\" srcset=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-400x167.jpg 400w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-1300x542.jpg 1300w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-768x320.jpg 768w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-1536x640.jpg 1536w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-430x179.jpg 430w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-700x292.jpg 700w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1-150x63.jpg 150w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/GTXGN-12-24-\u7cfb\u5217-\u56fa\u4f53\u7edd\u7f18\u73af\u7f51\u5f00\u5173\u67dc-1.jpg 1920w\" sizes=\"(max-width: 400px) 100vw, 400px\" title=\"\"><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__avatar\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/\" >\n\t\t\t\tGTXGN Painel de distribui\u00e7\u00e3o de rede em anel com isolamento s\u00f3lido\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/solid-insulated-ring-network-switchgear\/\" aria-label=\"Read more about GTXGN Solid Insulated Ring Network Switchgear\" tabindex=\"-1\" >\n\t\t\tLer mais \"\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-30485 page type-page status-publish has-post-thumbnail hentry\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fixed-ac-metal-enclosed-switchgear\/\" tabindex=\"-1\" ><div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"167\" src=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-400x167.png\" class=\"attachment-medium size-medium wp-image-30711\" alt=\"\u00a0Painel de distribui\u00e7\u00e3o met\u00e1lico fixo AC XGN\u00a0\" srcset=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-400x167.png 400w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-1300x542.png 1300w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-768x320.png 768w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-1536x640.png 1536w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-430x179.png 430w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-700x292.png 700w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1-150x63.png 150w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/XGN15-12SF6-Unit-AC-Metal-enclosed-Ring-Network-Switchge-1.png 1920w\" sizes=\"(max-width: 400px) 100vw, 400px\" title=\"\"><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__avatar\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fixed-ac-metal-enclosed-switchgear\/\" >\n\t\t\t\tPainel de distribui\u00e7\u00e3o met\u00e1lico fixo AC XGN\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fixed-ac-metal-enclosed-switchgear\/\" aria-label=\"Read more about XGN Fixed AC Metal Enclosed Switchgear\" tabindex=\"-1\" >\n\t\t\tLer mais \"\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-30484 page type-page status-publish has-post-thumbnail hentry\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/removable-ac-metal-clad-switchgear\/\" tabindex=\"-1\" ><div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"167\" src=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-400x167.jpg\" class=\"attachment-medium size-medium wp-image-30712\" alt=\"Painel de distribui\u00e7\u00e3o AC remov\u00edvel KYN revestido a metal\" srcset=\"https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-400x167.jpg 400w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-1300x542.jpg 1300w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-768x320.jpg 768w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-1536x640.jpg 1536w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-2048x853.jpg 2048w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-430x179.jpg 430w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-700x292.jpg 700w, https:\/\/electricalcabinet.net\/wp-content\/uploads\/2024\/06\/1ad86a55bd5cca3952334a1f07861290-1-150x63.jpg 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" title=\"\"><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__avatar\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/removable-ac-metal-clad-switchgear\/\" >\n\t\t\t\tPainel de distribui\u00e7\u00e3o AC remov\u00edvel KYN revestido a metal\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/removable-ac-metal-clad-switchgear\/\" aria-label=\"Read more about KYN Removable AC Metal Clad Switchgear\" tabindex=\"-1\" >\n\t\t\tLer mais \"\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8e0099bf e-flex e-con-boxed e-con e-parent\" data-id=\"8e0099bf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e3a4a9f0 wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"e3a4a9f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"title-wrapper set-mb-s reset-last-child wd-title-color-default wd-title-style-default wd-title-size-large text-center\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h2 class=\"woodmart-title-container title wd-fontsize-xxl\">Key Specifications &amp; Options<\/h2> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d3482ce color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"4d3482ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The configuration below reflects the options we build to order for GTXGN-12\/24 solid insulated ring network switch cabinets. Every parameter can be adjusted to match your drawings and site conditions \u2014 send us your requirements and our engineers will confirm what applies to your project.<\/p><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"text-align:left;padding:8px 10px;border-bottom:2px solid #e5e5e5;\">Parameter<\/th><th style=\"text-align:left;padding:8px 10px;border-bottom:2px solid #e5e5e5;\">Options \/ Typical Range<\/th><\/tr><\/thead><tbody><tr><td><strong>Rated voltage<\/strong><\/td><td>12 kV \/ 24 kV distribution systems<\/td><\/tr><tr><td><strong>Arc interruption<\/strong><\/td><td>Vacuum interrupters for switching duty<\/td><\/tr><tr><td><strong>Disconnector<\/strong><\/td><td>Direct-acting isolation switch with clear position indication<\/td><\/tr><tr><td><strong>Insulation system<\/strong><\/td><td>Solid composite environmentally friendly insulating materials \u2014 gas-free construction<\/td><\/tr><tr><td><strong>Unit arrangement<\/strong><\/td><td>Ring-in, ring-out, and transformer tee-off units combined per network position<\/td><\/tr><tr><td><strong>Earthing<\/strong><\/td><td>Integrated earthing switch positions per unit configuration<\/td><\/tr><tr><td><strong>Applicable standards<\/strong><\/td><td>GB 3906 corresponding to IEC 62271-200<\/td><\/tr><tr><td><strong>Typical applications<\/strong><\/td><td>SF6-free ring main units, compact substations, environmentally restricted sites, distribution automation<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8de4567c e-flex e-con-boxed e-con e-parent\" data-id=\"8de4567c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c11e9a7 wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"0c11e9a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"title-wrapper set-mb-s reset-last-child wd-title-color-default wd-title-style-default wd-title-size-large text-center\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h2 class=\"woodmart-title-container title wd-fontsize-xxl\">Perguntas mais frequentes<\/h2> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8bbc46b5 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"8bbc46b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Solid insulation or gas-filled construction for a ring main unit?<\/h3>\n<p>Solid insulation seals the switching function in cast insulating material \u2014 no gas inventory to monitor, no pressure alarms, and no SF6 accounting; gas-filled cabinets remain more compact per bay and are the long-proven route. Both meet GB 3906 \/ IEC 62271-200; the choice follows site conditions and environmental policy.<\/p>\n<h3>What maintenance does a solid-insulated unit need?<\/h3>\n<p>The encapsulated vacuum interrupter and disconnector are essentially maintenance-free over long intervals; service work concentrates on mechanisms, interlocks, and cable connections, which remain accessible. We provide the inspection schedule with the delivered units.<\/p>\n<h3>Does the direct-acting disconnector give a visible isolation position?<\/h3>\n<p>It gives a defined, indicated isolated position driven by a straight-line operating mechanism \u2014 the position indication is engineered for the switching sequence it serves. For supply-isolation procedures, follow the operating instructions delivered with the cabinet.<\/p>\n<h3>Which standards apply?<\/h3>\n<p>The cabinets are designed to GB 3906, corresponding to IEC 62271-200 for metal-enclosed MV switchgear. We reference the standards in design and deliver test and routine documentation with each unit.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ea70467d e-flex e-con-boxed e-con e-parent\" data-id=\"ea70467d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f7b0f8ab wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"f7b0f8ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"title-wrapper set-mb-s reset-last-child wd-title-color-default wd-title-style-default wd-title-size-large text-center\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h2 class=\"woodmart-title-container title wd-fontsize-xxl\">Related Guides<\/h2> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-418a0a98 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"418a0a98\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/electricalcabinet.net\/pt\/what-is-a-ring-main-unit\/\">Ring Main Unit (RMU) Guide: Functions, Components, and Selection Inputs<\/a> \u2014 what a ring main unit does in MV networks<\/li>\n<li><a href=\"https:\/\/electricalcabinet.net\/pt\/ring-main-unit-vs-switchgear\/\">Ring Main Unit vs Switchgear: What Is The Difference?<\/a> \u2014 where RMUs end and switchgear begins<\/li>\n<li><a href=\"https:\/\/electricalcabinet.net\/pt\/medium-voltage-switchgear-guide\/\">Medium-Voltage-Switchgear Guide: Functions, Components, and Selection Inputs<\/a> \u2014 the MV framework around ring cabinets<\/li>\n<li><a href=\"https:\/\/electricalcabinet.net\/pt\/electrical-switchgear\/high-voltage-switchgear\/fully-sealed-and-fully-insulated-inflatable-ring-network-switchgear\/\">Fully Sealed Inflatable Ring Network Switchgear<\/a> \u2014 the gas-filled counterpart of this SF6-free family<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>GTXGN-12\/24 series solid insulated ring network switch cabinet is the main unit switch of solid composite insulated ring network used<\/p>","protected":false},"author":1,"featured_media":30710,"parent":30154,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-30518","page","type-page","status-publish","has-post-thumbnail","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/pages\/30518","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/comments?post=30518"}],"version-history":[{"count":13,"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/pages\/30518\/revisions"}],"predecessor-version":[{"id":35718,"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/pages\/30518\/revisions\/35718"}],"up":[{"embeddable":true,"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/pages\/30154"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/media\/30710"}],"wp:attachment":[{"href":"https:\/\/electricalcabinet.net\/pt\/wp-json\/wp\/v2\/media?parent=30518"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}